scsi: megaraid_sas: Update LD map after populating drv_map driver map copy
authorShivasharan S <shivasharan.srikanteshwara@broadcom.com>
Fri, 5 Jan 2018 13:27:44 +0000 (05:27 -0800)
committerMartin K. Petersen <martin.petersen@oracle.com>
Thu, 11 Jan 2018 04:25:17 +0000 (23:25 -0500)
commit5f19f7c879c4aacdb54d02a79e19d97064c9c999
tree70e6979a7d7c5e6c61ad48434d40624db320d8a9
parent619831f23bf76e7d420991df3baefc8e24cc5432
scsi: megaraid_sas: Update LD map after populating drv_map driver map copy

Issue – There may be some IO accessing incorrect raid map, but driver
has checks in IO path to handle those cases. It is always better to move
to new raid map only once raid map is populated and validated.  No
functional defect. Fix is provided as part of review.  Fix – Update
instance->map_id after driver has populated new driver raid map from
firmware raid map.

Signed-off-by: Sumit Saxena <sumit.saxena@broadcom.com>
Signed-off-by: Shivasharan S <shivasharan.srikanteshwara@broadcom.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/megaraid/megaraid_sas.h
drivers/scsi/megaraid/megaraid_sas_base.c
drivers/scsi/megaraid/megaraid_sas_fp.c
drivers/scsi/megaraid/megaraid_sas_fusion.c