power_supply: remove capacity_level from list of sysfs attributes
authorThadeu Lima de Souza Cascardo <cascardo@minaslivre.org>
Thu, 7 Feb 2008 08:13:20 +0000 (00:13 -0800)
committerLinus Torvalds <torvalds@woody.linux-foundation.org>
Thu, 7 Feb 2008 16:42:06 +0000 (08:42 -0800)
commit4cbc76eadf56399cd11fb736b33c53aec9caab8c
tree215ec5236611d766a504ef60fc346c9217d8c1e5
parentb1e058da50f7938e9c9e963e978b0730bba4ad32
power_supply: remove capacity_level from list of sysfs attributes

This commit:

commit 8efe444038a205e79b38b7ad03878824901849a8
Author: Andres Salomon <dilinger@queued.net>
Date:   Wed Dec 12 14:12:56 2007 -0500

    power: remove POWER_SUPPLY_PROP_CAPACITY_LEVEL

Removed CAPACITY_LEVEL from every other code, leaving the array with sysfs
attributes with one more entry than the number of enums in power_supply.h.
This leads to some attributes containing the value of the attribute right
after it.  For example, temp_ambient would have the value of
time_to_empty_now.  In my case, I had time_to_full_avg have the value which
should be in model_name, when the former was usually empty.

Cc: Andres Salomon <dilinger@debian.org>
Cc: David Woodhouse <dwmw2@infradead.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
drivers/power/power_supply_sysfs.c