cxl: Set the PBCQ Tunnel BAR register when enabling capi mode
Skiboot used to set the default Tunnel BAR register value when capi
mode was enabled. This approach was ok for the cxl driver, but
prevented other drivers from choosing different values.
Skiboot versions > 5.11 will not set the default value any longer.
This patch modifies the cxl driver to set/reset the Tunnel BAR
register when entering/exiting the cxl mode, with
pnv_pci_set_tunnel_bar().
That should work with old skiboot (since we are re-writing the value
already set) and new skiboot.
mpe: The tunnel support was only merged into Linux recently, in commit
d6a90bb83b50 ("powerpc/powernv: Enable tunneled operations")
(v4.17-rc1), so with new skiboot kernels between that commit and this
will not work correctly.
Fixes: d6a90bb83b50 ("powerpc/powernv: Enable tunneled operations")
Signed-off-by: Philippe Bergheaud <felix@linux.ibm.com>
Reviewed-by: Christophe Lombard <clombard@linux.vnet.ibm.com>
Acked-by: Frederic Barrat <fbarrat@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>