serial: Z85C30: avoid a hang at console switch-over
authorMaciej W. Rozycki <macro@linux-mips.org>
Thu, 24 Jul 2008 04:29:48 +0000 (21:29 -0700)
committerLinus Torvalds <torvalds@linux-foundation.org>
Thu, 24 Jul 2008 17:47:29 +0000 (10:47 -0700)
commit377135912806ddc87d56d64fafa685f4063c45f1
tree77165d6a19281278d54c0b054ffacf7472bd093e
parentb76c5a0717094f0a900d9afd8e36f7ad8dbba587
serial: Z85C30: avoid a hang at console switch-over

Changes to the generic console support code that happened a while ago
introduced a scenario where the initial console is used in parallel with
the final console during a brief period when switching between the two is
in progress.  During that time a message about the switch-over is printed.

With some combinations of chips, firmware and drivers, such as the Zilog
Z85C30 SCC used with the DECstation, a hang may happen because the
firmware used for the initial console may not expect the state of the chip
after it has been initialised by the driver.  This is not a bug in the
firmware, as some registers it would have to examine are write-only.

This is a workaround for the Z85C30 which reuses the power-management
callback to keep the transmitter of the line associated with the console
enabled.  It reflects the consensus reached in a discussion a while ago.

Signed-off-by: Maciej W. Rozycki <macro@linux-mips.org>
Cc: Jiri Slaby <jirislaby@gmail.com>
Cc: Alan Cox <alan@lxorguk.ukuu.org.uk>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
drivers/serial/zs.c