staging: comedi: pcl812: tidy up the analog input (*insn_read)
For aesthetics, move this function out of the async command support
code.
For safety, the INT request (end-of-conversion flag) should be cleared
before doing each conversion and after the final data sample is read.
The driver currently does not do this.
Refactor the function a bit so it's more like the pcl818 and pcl816
drivers and use common code to clear the flag for a timeout and after
the last sample.
Do a bit of other tidying up during the move.
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>