hwmon: (lm75) Tune resolution and sample time per chip
authorJean Delvare <khali@linux-fr.org>
Sat, 4 May 2013 12:49:36 +0000 (14:49 +0200)
committerJean Delvare <khali@endymion.delvare>
Sat, 4 May 2013 12:49:36 +0000 (14:49 +0200)
commit0cd2c72d765191f24d7be14366c0413bf139f3e3
tree77d19cabe37cd11b6c5c5f14e8e5dc05da81802f
parent87d0621ae2bdf2e2c60aadbbcb8b6c680777c1bf
hwmon: (lm75) Tune resolution and sample time per chip

Most LM75-compatible chips can either sample much faster or with a
much better resolution than the original LM75 chip. So far the lm75
driver did not let the user take benefit of these improvements. Do it
now.

I decided to almost always configure the chip to use the best
resolution possible, which also means the longest sample time. The
only chips for which I didn't are the DS75, DS1775 and STDS75, because
they are really too slow in 12-bit mode (1.2 to 1.5 second worst case)
so I went for 11-bit mode as a more reasonable tradeoff. This choice is
dictated by the fact that the hwmon subsystem is meant for system
monitoring, it has never been supposed to be ultra-fast, and as a
matter of fact we do cache the sampled values in almost all drivers.

If anyone isn't pleased with these default settings, they can always
introduce a platform data structure or DT support for the lm75. That
being said, it seems nobody ever complained that the driver wouldn't
refresh the value faster than every 1.5 second, and the change made
it faster for all chips even in 12-bit mode, so I don't expect any
complaint.