1 From f220efa380854e2423a47f26acde9355ae016ea3 Mon Sep 17 00:00:00 2001
2 From: Serge Schneider <serge@raspberrypi.org>
3 Date: Tue, 2 Oct 2018 11:14:15 +0100
4 Subject: [PATCH] drivers: thermal: step_wise: avoid throttling at
5 hysteresis temperature after dropping below it
7 Signed-off-by: Serge Schneider <serge@raspberrypi.org>
9 drivers/thermal/gov_step_wise.c | 2 +-
10 1 file changed, 1 insertion(+), 1 deletion(-)
12 --- a/drivers/thermal/gov_step_wise.c
13 +++ b/drivers/thermal/gov_step_wise.c
14 @@ -155,7 +155,7 @@ static void thermal_zone_trip_update(str
16 if (tz->temperature >= trip_temp ||
17 (tz->temperature >= hyst_temp &&
18 - old_target != THERMAL_NO_TARGET)) {
19 + old_target == instance->upper)) {
21 trace_thermal_zone_trip(tz, trip, trip_type);